DC reactor

Product introduction
DC reactor is also called the flat wave reactor, used in DC side converter, DC current flowing in the reactor has an AC component. The main purpose is to limit the AC component superimposed on the DC current, current waveform distortion caused by the improvement of capacitance filter, reduce current ripple value, improve the power factor converter, harmonic suppression converter inverter produces, reduce their impact on the rectifying device and the power grid.
Application field
DC reactor is mainly used for the frequency converter and electric locomotive
Technical parameters
1, rated current: less than 1600A
2, the dielectric strength: winding - 3000VAC/50Hz/60s no flashover breakdown
3, insulation resistance: winding -, piercing screw - 500VDC, insulation resistance value is more than 100M Omega
4, the reactor noise: less than 65dB (with reactor level distance from point 1 meters test)
5, protection grade: IP00
6, insulation grade: H
7, product executive standard: IEC289:1987 reactor, GB10229-88 reactor (EQV IEC289:1987)
Conditions of use
1, an altitude of more than 1000 meters, more than 1000 meters derating.
2, the operating environment temperature between -25 DEG ~+40 DEG C, relative humidity of not more than 90%.
3, no harmful gas, inflammable and explosive materials, no conductive dust.
DC reactor is also called the flat wave reactor, used in DC side converter, DC current flowing in the reactor has an AC component. The main purpose is to limit the AC component superimposed on the DC current, current waveform distortion caused by the improvement of capacitance filter, reduce current ripple value, improve the power factor converter, harmonic suppression converter inverter produces, reduce their impact on the rectifying device and the power grid.
Application field
DC reactor is mainly used for the frequency converter and electric locomotive
Technical parameters
1, rated current: less than 1600A
2, the dielectric strength: winding - 3000VAC/50Hz/60s no flashover breakdown
3, insulation resistance: winding -, piercing screw - 500VDC, insulation resistance value is more than 100M Omega
4, the reactor noise: less than 65dB (with reactor level distance from point 1 meters test)
5, protection grade: IP00
6, insulation grade: H
7, product executive standard: IEC289:1987 reactor, GB10229-88 reactor (EQV IEC289:1987)
Conditions of use
1, an altitude of more than 1000 meters, more than 1000 meters derating.
2, the operating environment temperature between -25 DEG ~+40 DEG C, relative humidity of not more than 90%.
3, no harmful gas, inflammable and explosive materials, no conductive dust.