Inverter output transformer

Product introduction
The inverter output transformer for inverter side converter, the voltage inverter output into the load voltage needed, and to provide isolation between the load and the inverter, and the output end of the capacitive reactance is integrated together, reduce the content of harmonic current line, filter the carrier on the clutter reduction, sine wave output voltage.
Application field
The inverter output transformer used in the data center
Technical parameters
1, the rated power range is less than or equal to 1600KVA
2, the dielectric strength: winding - winding, winding - 3000VAC/50HZ/60s without flying fox breakdown
3, insulation resistance: through screw - 500VDC, insulation resistance value is more than 100M Omega
4, the transformer noise: less than 65dB (and transformer horizontal distance point 1 meters test)
5, protection grade: IP00
6, insulation grade: H
7, product executive standard: IEC726-11 dry type power transformer, dry-type power transformer GB1094.11-2007, IEEE.C57.12.01-2005 dry type distribution and power transformers for general requirements
Conditions of use
1, an altitude of more than 1000 meters, more than 1000 meters derating.
2, the operating environment temperature between -5 DEG ~+40 DEG C, relative humidity of not more than 90%
3, no harmful gas, inflammable and explosive materials, no conductive dust.
The inverter output transformer for inverter side converter, the voltage inverter output into the load voltage needed, and to provide isolation between the load and the inverter, and the output end of the capacitive reactance is integrated together, reduce the content of harmonic current line, filter the carrier on the clutter reduction, sine wave output voltage.
Application field
The inverter output transformer used in the data center
Technical parameters
1, the rated power range is less than or equal to 1600KVA
2, the dielectric strength: winding - winding, winding - 3000VAC/50HZ/60s without flying fox breakdown
3, insulation resistance: through screw - 500VDC, insulation resistance value is more than 100M Omega
4, the transformer noise: less than 65dB (and transformer horizontal distance point 1 meters test)
5, protection grade: IP00
6, insulation grade: H
7, product executive standard: IEC726-11 dry type power transformer, dry-type power transformer GB1094.11-2007, IEEE.C57.12.01-2005 dry type distribution and power transformers for general requirements
Conditions of use
1, an altitude of more than 1000 meters, more than 1000 meters derating.
2, the operating environment temperature between -5 DEG ~+40 DEG C, relative humidity of not more than 90%
3, no harmful gas, inflammable and explosive materials, no conductive dust.